Publicación:
Ultrasound pre-treatment enhances the carrot drying and rehydration

dc.contributor.author Ricce C. es_PE
dc.contributor.author Rojas M.L. es_PE
dc.contributor.author Miano A.C. es_PE
dc.contributor.author Siche R. es_PE
dc.contributor.author Augusto P.E.D. es_PE
dc.date.accessioned 2024-05-30T23:13:38Z
dc.date.available 2024-05-30T23:13:38Z
dc.date.issued 2016
dc.description The authors are grateful to the São Paulo Research Foundation (FAPESP, Brazil) for funding the project n° 2014/16998-3 and the National Council for Scientific and Technological Development (CNPq, Brazil) for funding the project n° 401004/2014-7. The authors are also grateful to Cienciactiva for the A.C. Miano Ph.D. (CONCYTEC, Peru; Contract 272-2015-FONDECYT) and M.L. Rojas Ph.D. (CONCYTEC, Peru; Contract 087-2016-FONDECYT) scholarships, from the “Consejo Nacional de Ciencia, Tecnología e Inovación Tecnológica”.
dc.description.abstract The present work aimed to describe the mechanisms involved in the enhancement of the drying and rehydration process of carrot slices caused by the pre-treatment using the ultrasound technology. For that, carrot slices of 4 mm of thickness were pre-treated for 30 and 60 min using an ultrasonic bath (41 W/L; 25 kHz). The convective drying process was performed at 40 and 60 °C with 2.0 m/s of air velocity, while the rehydration process was performed at 25 °C. The Henderson & Pabis model was used to describe the drying kinetics and the Peleg model to describe the rehydration process of the carrots slices. As a result, the drying and rehydration kinetics were described, at the different conditions of process, correlating the results with the main effects that the ultrasound cause as a pre-treatment (cell bloating and micro-channels) and the air-drying temperature. Depending on the length of the pre-treatment, the effects caused by the ultrasound in the following processes were different. In addition, it was corroborated that when the drying temperature is increased, less evidenced is the ultrasound effect. The ultrasound, when is applied for long times, enhanced the drying and further rehydration rate at low temperatures, due to the tissue damage. Moreover, vacuum-packed samples were pre-treated with ultrasound in order to exclude the water gain and to evaluate only the micro-channels formation effect. It was concluded that the ultrasound pre-treatment enhances the drying and rehydration processes; however, future optimization studies are recommended.
dc.description.sponsorship Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - Concytec
dc.identifier.doi https://doi.org/10.1016/j.foodres.2016.09.030
dc.identifier.scopus 2-s2.0-85000365260
dc.identifier.uri https://hdl.handle.net/20.500.12390/812
dc.language.iso eng
dc.publisher Elsevier Ltd
dc.relation.ispartof Food Research International
dc.rights info:eu-repo/semantics/openAccess
dc.subject Ultrasound technology
dc.subject Air es_PE
dc.subject Heat convection es_PE
dc.subject Ultrasonics es_PE
dc.subject Convective drying es_PE
dc.subject Drying temperature es_PE
dc.subject Optimization studies es_PE
dc.subject Rehydration es_PE
dc.subject Rehydration kinetic es_PE
dc.subject Rehydration process es_PE
dc.subject Ultrasound pre treatments es_PE
dc.subject Drying es_PE
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#4.04.00
dc.title Ultrasound pre-treatment enhances the carrot drying and rehydration
dc.type info:eu-repo/semantics/article
dspace.entity.type Publication
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
Archivos