Publicación:
Influence of Steel Bars in Detection of Voids in Concrete Using Ultrasonic Pulse-Echo Method

dc.contributor.author Lipa, L es_PE
dc.contributor.author Navarro, LM es_PE
dc.contributor.author Pasquel, EN es_PE
dc.date.accessioned 2024-05-30T23:13:38Z
dc.date.available 2024-05-30T23:13:38Z
dc.date.issued 2019
dc.description This project was carried out thanks to the scholarship funds for postgraduate studies of CONCYTEC PERU. Also, the tests were performed at the Structures Laboratory of the Pontifical Catholic University of Peru.
dc.description.abstract In this research, the influence of steel bars in the detection of voids in concrete elements using the ultrasonic pulse-echo method was analyzed. For this purpose, reinforced concrete walls were made that contain No. 3, No. 4, or No. 5 steel bars, and expanded polystyrene spheres 50 mm (1.97 in.) in diameter, which represent internal voids. Spheres of smaller diameter were not used because their detection is very low. An ultrasonic pulse-echo device of 50 kHz frequency transverse waves that uses a synthetic aperture focusing technique (SAFT) was used. The steel bars were placed with different separations to observe the effect they cause in a scan. In addition, the spheres were laid between these different configurations with the purpose of verifying if their detection is possible. Additionally, image processing was carried out to eliminate or totally reduce the effect of the steel bars in the scans. This research concluded that when scans are performed on strips with transverse No. 3, No. 4, and No. 5 bars, these would appear in the ultrasound image with a probability of 35.4%, 41.7%, and 62.5%, respectively. In addition, if the scan is performed on a strip with No. 4 or No. 5 bars, which have the same direction of the scan, they appear in large magnitude in the ultrasound images, so it is very difficult to distinguish if there is another material in these areas. However, in this last case, if the bars are No. 3, they do not appear in the scan. On the other hand, the spheres were located with a probability of 81.3% when they were located between steel bars separated by a distance greater than or equal to 100 mm (1.97 in.).
dc.description.sponsorship Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - Concytec
dc.identifier.doi https://doi.org/10.14359/51715582
dc.identifier.isi 478070000024
dc.identifier.uri https://hdl.handle.net/20.500.12390/1185
dc.language.iso eng
dc.publisher American Concrete Institute
dc.relation.ispartof ACI Materials Journal
dc.rights info:eu-repo/semantics/openAccess
dc.subject Voids
dc.subject Flaw detection es_PE
dc.subject Honeycombs es_PE
dc.subject Pulse echo es_PE
dc.subject Reinforced concrete es_PE
dc.subject Ultrasonic es_PE
dc.subject.ocde https://purl.org/pe-repo/ocde/ford#2.01.03
dc.title Influence of Steel Bars in Detection of Voids in Concrete Using Ultrasonic Pulse-Echo Method
dc.type info:eu-repo/semantics/article
dspace.entity.type Publication
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
oairecerif.author.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE#
Archivos