Integrated microfluidic preconcentration and nucleic amplification system for detection of influenza a virus H1N1 in saliva

dc.contributor.author Kim Y. es_PE
dc.contributor.author Abafogi A.T. es_PE
dc.contributor.author Tran B.M. es_PE
dc.contributor.author Kim J. es_PE
dc.contributor.author Lee J. es_PE
dc.contributor.author Chen Z. es_PE
dc.contributor.author Bae P.K. es_PE
dc.contributor.author Park K. es_PE
dc.contributor.author Shin Y.-B. es_PE
dc.contributor.author Noort D.V. es_PE
dc.contributor.author Lee N.Y. es_PE
dc.contributor.author Park S. es_PE
dc.date.accessioned 2024-05-30T23:13:38Z
dc.date.available 2024-05-30T23:13:38Z
dc.date.issued 2020
dc.description.abstract InfluenzaAviruses are often present in environmental and clinical samples at concentrations below the limit of detection (LOD) of molecular diagnostics. Here we report an integrated microfluidic preconcentration and nucleic amplification system (?FPNAS) which enables both preconcentration of influenza A virus H1N1 (H1N1) and amplification of its viral RNA, thereby lowering LOD for H1N1. H1N1 virus particles were first magnetically preconcentrated using magnetic nanoparticles conjugated with an antibody specific for the virus. Their isolated RNA was amplified to cDNA through thermocycling in a trapezoidal chamber of the ?FPNAS. A detection limit as low as 100 TCID50 (50% tissue culture infective dose) in saliva can be obtained within 2 hours. These results suggest that the LOD of molecular diagnostics for virus can be lowered by systematically combining immunomagnetic separation and reverse transcriptase-polymerase chain reaction (RT-PCR) in one microfluidic device. © 2020 by the authors.
dc.description.sponsorship Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - Concytec
dc.identifier.doi https://doi.org/10.3390/mi11020203
dc.identifier.scopus 2-s2.0-85081271951
dc.identifier.uri https://hdl.handle.net/20.500.12390/2582
dc.language.iso eng
dc.publisher MDPI AG
dc.relation.ispartof Micromachines
dc.rights info:eu-repo/semantics/openAccess
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject Molecular amplification
dc.subject H1N1 es_PE
dc.subject Immunomagnetic separation es_PE
dc.subject Microfluidic device es_PE
dc.subject.ocde http://purl.org/pe-repo/ocde/ford#3.03.09
dc.title Integrated microfluidic preconcentration and nucleic amplification system for detection of influenza a virus H1N1 in saliva