Publicación:
Characterization of healthy skin with high-frequency ultrasound using quantitative ultrasound

dc.contributor.author Saavedra Bazán, Ana Cecilia es_PE
dc.date.accessioned 2024-05-30T23:13:38Z
dc.date.available 2024-05-30T23:13:38Z
dc.date.issued 2018
dc.description.abstract The skin is the largest organ of the body that protects it from the external environment. High- frequency ultra sound (HF-US) has been used to visualize the skin in depth and to diagnose some pathologies in dermatological applications. Quantitative ultrasound (QUS) includes several techniques that provide values of particular physical properties. In this thesis work, three QUS parameters are explained and used to characterize healthy skin through HF-US: attenuation coefficient slope (ACS), backscatter coefficient (BSC) and shear wave speed (SWS). They were estimated with the regularized spectral-log difference (RSLD) method, the reference phan- tom method, and the crawling wave sonoelastography method, respectively. All the three parameters were assessed in phantoms, ex vivo and in vivo skin. In calibrated phantoms, RSLD showed a reduc- tion of up to 93% of the standard deviation concerning the estimation with SLD, and BSC showed an agreement with the Faran’s theoretical curve. In gelatin-based phantoms, surface acoustic waves (SAWs) were estimated in two interfaces: solid-water and solid-US gel, which all owed corroborating SAWs presence and finding an empirical compensation factor when the coupling interface is US gel. A correction factor of 0:97 for SAW-to-shear was found to avoid underestimation in phantoms. Porcine thigh was calculated in the range from 8 to 27 MHz, where the ACS was 4:08 _+_0:43 dB cm -1 MHz-1 and BSC was in the range from 10 1 to 10° sr-1 _cm-1. Crawling wave sonoelastography method was applied for the vibration frequencies between 200 Hz and 800 Hz, where SWS was in the range from 4:6 m/sto9:1 m/s. In vivo ACS and BSC were assessed in the healthy forearm and thigh, whereas SWS only in the thigh. The average ACS in the forearm dermis was 2.07dB cm-1 _MHz-1, which is in close agreement with the literature. A significant difference (p < 0.05) was found between the ACS in the forearm dermis and the thigh dermis (average ACS of 2.54dB cm-1 _MHz-1). The BSC of the forearm and thigh dermis were in the range from 10 -1 to 10° sr-1 _cm-1, and in the range from 10-1 to 10° sr-1 _cm-1, respectively. The SWS in the thigh dermis was 2:4 _+_0:38 m/s for a vibration frequency of 200Hz, with an increasing trend as frequency increases. Results suggest that these QUS parameters have the potential to be used as a tool for in vivo skin characterization and show potential for future application in skin lesions. en
dc.description.sponsorship Consejo Nacional de Ciencia, Tecnología e Innovación Tecnológica - Concytec
dc.identifier.uri https://hdl.handle.net/20.500.12390/1515
dc.language.iso eng
dc.publisher Pontificia Universidad Católica del Perú
dc.rights info:eu-repo/semantics/openAccess
dc.subject Ultrasonido en medicina
dc.subject Procesamiento de imágenes digitales es_PE
dc.subject Enfermedades es_PE
dc.title Characterization of healthy skin with high-frequency ultrasound using quantitative ultrasound
dc.type info:eu-repo/semantics/masterThesis
dspace.entity.type Publication
Archivos